Disclaimer

The solutions provided in this blog are solutions that are tested in our CUSTOM environment. Others come from Vendor's Technical Support Libraries and others not. Please make sure that you know what you are doing and note that we don't bring any responsibility in case of a break down.

Monday 9 June 2008

STOP C0000139 {Entry Point Not Found} after XP SP3 Installation

After installing SP3 on a machine running Windows XP SP2 and just after the reboot I got a blue screen with the following error:

STOP C0000139 {Entry Point not Found}
The procedure entry point GdiGetBitmapBitSize could not be located in the dynamic link library GDI32.dll.

After searching for not more than 2 mins in the net I found the solution which I know give to you below.

1. Boot from a Windows CD and choose the repair option.
2. Browse to
c:\windows\servicepackfiles\i386\ and copy gdi32.dll to c:\windows\system32\
3. Overwirte the old file.
4. Reboot and your On.

No comments: